NextGen Socio & Enviro Advisors

The Tamil Nadu Factories Rules, 1950

Arrangement of Rules

G.O. No. 1041 of 1950 · Tamil Nadu · 68 chapters and schedules, 167 rules

SCHEDULE - XI

CONVEYORS PART-A — GENERAL

1. Definition

For the purposes of this Schedule: “ Conveyor " means a horizontal, inclined, or vertical device for moving or transporting material of any kind, in a path determined by the design of the device, and having points of loading or discharge and the device shall include skip hoists, but shall not include devices like cranes, hoists, monorails, bucket drag lines, platform elevators, plant railways, cableways and tramways.

2. Design, construction and maintenance, etc

(1) Conveyor shall be of good design, proper construction, sound material, adequate strength and free from defects and shall be properly maintained.

(2) 'In running nips ' shall he securely fenced by safeguard of substantial construction or by any other suitable device.

(3) Conveyor shall be installed in such a way that a clearance of atleast 45 centimeters shall be provided between the conveyors side of the passage way and the conveyor. Hand rails or railings shall be provided on open sides of the walkway all along the belt.

(4) When workers have to cross over conveyor, regular crossing facilities affording safe passage shall be provided.

(5) Suitable device like gongs, whistles or signal lights shall be provided to the operator to warn the workers before starting the conveyor.

(6)

(a) The starting button or switch for the conveyor shall be so located that the operator can see as much of the conveyor as possible. The starting and stopping devices shall be marked distinctly and so located that they can be clearly seen and safely approached.

(b) All personnel working on or around the conveyor shall be made to have knowledge about the location and operation of all stopping devices.

(7) Side guard of sufficient height and strength shall be provided to prevent falling of material from the conveyor.

(8)

(a) conveyors shall be tested and the parts thereof thoroughly examined by a competent person before being taken into use for the first time or after it has undergone any alteration or major repairs liable to affect its strength or stability.

(b) A certificate of such tests and examinations signed by the competent person making the tests and examinations specifying the maximum safe conveying load shall be obtained and made available to the Inspector on demand.

(c) Conveyors shall be thoroughly examined atleast once in every twelve months by the competent person and report of the competent person shall be made available to the Inspector on demand.

(9) Belt conveyors carrying materials which might stick to tail drums or belts, shall be provided with fixed scrappers or revolving brushes for removing the deposits to avoid the hazards in cleaning the moving parts or pulleys by hand or shovels while the belts are in motion.

(10) Conveyors shall be provided with automatic and continuous lubrication systems or with lubricating facilities so arranged that oiling and greasing can be performed without the oils coming within the dangerous proximity to moving pans.

(11) Before commencing any maintenance work, electrical or mechanical, ' permit ' to work shall be obtained from the manager or any person so authorized by the manager for the purpose and the procedure laid down in the permit shall be strictly followed.

(12) The workers working on conveyor shall be adequately trained.

(13) No person shall be required or allowed to ride on conveyors.

3. Conveyor Guarding

(1) The Underpasses of the conveyor shall be securely guarded.

(2) All the transfer points of conveyors system shall be adequately enclosed.

(3) Where the top of hopper for feeding conveyor is less than 90 centimeters above floor, the opening shall be adequately guarded.

(4) All the areas underneath the counterweight of the conveyor system shall be suitable

(sic) barricaded so as to prevent any person getting injured due to accidental fall of the ' counterweight '.

(5) Gears, sprockets, sheaves and other moving parts shall be either adequately guarded or positioned in such a way as to protect workers against personal injuries.

4. Safety Devices

(1) A conveyor shall

(i) stop when its driving power is cut-off and remain stopped until the power is reconnected;

(ii) have a provision at each point of loading or delivery of the conveyor, to stop the conveyor;

(iii) not be capable of being restarted after having been stopped until the device, if any, by which it is stopped is reset in the running position; and

(iv) where the conveyor can be stopped by means of a push button have provision whereby the push button can be secured in the stop position.

(2)

(a) Chord shall be provided on both sides of the belt along the walkway covering the entire length of the belt when pulled shall stop the conveyor and the distance between two consecutive emergency stopping devices of the chords shall not exceed 23 (twenty three) meters.

(b) For conveyers other than belt conveyors emergency stopping devices shall be provided at the accessible points throughout the length of the conveyors and distance between the two consecutive devices shall not be more than 8 (eight) meters.

(3) Overload protection device shall be provided so that when overloaded all starting devices shall get automatically tripped off. In addition to such overload protection customarily provided for electric motors, there shall be an overload device designed to protect the conveyor and mechanical drive parts. In the event of an overload, the device shall shut off the electric power quickly, disconnect the conveyor or drive parts from the motive power, or limit the applied torque.

(4) When a conveyor has stopped because of an overload, all starting devices shall be locked out and the cause of the overload removed. The entire conveyor shall be inspected before it is restarted.

(5) If two or more conveyers are operated in series, conveyors shall be interlocked in such a way that if one conveyor is stopped all other conveyors fed by it shall be stopped simultaneously.

(6) Conveyors which carry loads up inclines shall be provided with mechanical devices that will prevent machinery from reversing and carrying the loads back towards the loading point in the event of the power being cut-off.

(7) The precautions necessary to avoid the accumulation of the static electricity shall be taken.

5. Personal Protective Equipment

The worker engaged in the operation of conveyors shall wear tight fitting clothing and use appropriate personal protective equipment. PART-B SPECIAL TYPES OF CONVEYORS

6. Gravity Conveyers

(1) The delivery ends of the conveyors shall be provided with electrically or mechanically operated devices to give warning that a package is about to be delivered.

(2) To prevent the spread of fire, the chute conveyors shall be

(a) enclosed in shafts made of fire resisting materials, with a door at each charging station and at the delivery end; or

(b) provided with automatic fire doors or with draught checks where the chutes pass through the floors.

(3) The gravity roller conveyors shall be provided with guides or guard rails on each side of the conveyor way at corners or turns and on each side of those portions of the conveyor way which are more than 5 (five) feet above the floor.

7. Chain Conveyor

(1) Overhead chain conveyor systems shall be so designed and installed that ample clearance is provided between the material transported and any fixed or moving objects.

(2) Apron conveyors used for carrying unpacked bottles, jars or other glass containers shall be provided with side rails at a suitable distance above the conveying surfaces to prevent the containers from tipping over or falling off.

(3) Return portion of a chain conveyor shall be adequately guarded.

8. Bucket Conveyors

(1) Inclined bucket conveyors shall be enclosed with solid guards which,

(a) are not less than 7 (seven) feet in height, but preferably extend to the full height of the machinery, so as

(i) to prevent anything being pushed or thrown into the shaft ways; and

(ii) to hold any material which might drop from the buckets; and

(b) are provided with wire-glass windows or doors or with removable sections to facilitate inspection, cleaning and repairs.

(2) Controls of movable tripping devices for bucket conveyors shall be so located that they can be operated from a safe position.

9. Screw Conveyors

(1) Screw conveyors shall be placed in steel or steel-lined trough fitted with well- secured tight covers of not less than 3 (three) mm (1/8 inch) steel plates in removable sections and should be provided with second covers of heavy wire mesh in corresponding removable sections underneath the solid top covers so as to guard the screw when the solid cover is removed for inspection of the interior.

(2) Inside coven of screw conveyors, or outside covers where so inside covers are provided, should be mechanically or electrically interlocked with the control units or driving mechanisms in such a manner that the power is automatically shut off whenever a section of the cover is removed.

(3) No person shall be allowed/required to stand or walk on housings of screw conveyors.

10. Pneumatic Conveyors

(1) Blower or exhaust fans for pneumatic conveyors systems shall be —

(a) of non-combustible construction;

(b) of adequate but not greatly excessive capacity properly to perform the functions required;

(c) firmly secured to substantial supports or foundations.

(d) so located and arranged as to afford ready and safe access for cleaning inspection, lubrication and repairing; and

(e) provided with remote control in addition to any controls located close to the systems.

(2) Where readily ignitable materials are passed through fans for pneumatic conveyor systems, the blades and spiders of the fans shall be of non-ferrous material; or the casings shall be lined with non-ferrous material.

(3) Blades or runners of blower or exhaust fans for pneumatic conveyor systems shall be of sufficient strength to prevent contact with casings or distortion under conditions of deposit loading or other operating factors.

(4) Housing or casings of blower or exhaust fans for pneumatic conveyors shall be so constructed as to prevent distortion and loss of alignment under operating conditions.

(5) Intake openings of blowers or exhaust fans for pneumatic conveyors shall be protected with substantial metal screens or gratings.

(6) Bearing of blower or exhaust fans for pneumatic conveyors shall be self-lubricating, dust-tight, and located outside casings and ducts.

(7) Ducts for pneumatic conveyor systems shall be constructed of steel plate of adequate strength or other metal equal in strength to steel plate.

(8) Ducts for pneumatic conveyor systems shall be

(a) reasonably tight throughout, with no openings other than those required for the proper operation and maintenance of the systems;

(b) substantially supported by metal brackets or hangers, and thoroughly braced where required; and

(c) kept open and unobstructed throughout their entire length with no screens inside them.

(9) Hand holes for cleaning purposes in ducts for pneumatic conveyors shall be equipped with tight-fitting sliding or swinging doors pro-vided with substantial latches.

(10) Where material is fed by hand into pneumatic conveyors through openings 30 (thirty) centimeters 12 (twelve) inches or larger, provision shall be made to prevent worker from being drawn into the ducts, such as by installing feed hoppers extending at least I (one) meter-40 (forty inches) from the ducts.

(11) Doors of a pneumatic conveyor shall be so interlocked that they cannot be opened when there is positive internal pressure and the conveyor cannot be started unless all the doors are closed].