The Tamil Nadu Factories Rules, 1950
Arrangement of Rules
G.O. No. 1041 of 1950 · Tamil Nadu · 68 chapters and schedules, 167 rules
Chapter III
HEALTH
15.Cleanliness of walls and ceilings
The provision of clause (d) of sub-section (I) of section I of the Act shall not apply to the classes of factories or descriptions of factories or parts thereof specified in the Schedule below:
Provided that they are kept in a clean state by washing, sweeping, brushing, dusting, vacuum-cleaning or other effective means:
Provided further that the said clause (d) shall continue to apply
(i) in respect of factories or parts of factories specified in Part A of the schedule, to workrooms in which the amount of cubic space allowed for every person employed in the room is less than 500 cubic feet;
(ii) in respect of factories or parts of factories specified in Part B of the schedule, to workrooms in which the amount of cubic space allowed for every person employed in the room is less than 2,500 cubic feet;
(iii) to engine houses, fitting shops, lunch rooms, canteens, shelters, cr è ches, cloak rooms, rest rooms, and wash places; and
(iv) to such parts of walls, sides and tops of passages and staircases as are less than 20 feet above the floor or stair.]
If it appears to the Chief Inspector that any part of a factory, to which by virtue of sub-rule (I) any of the provisions of the said clause (d) do not apply, is not being kept in a clean state, he may by written notice require the occupier to whitewash or colour wash, wash, paint or varnish the same, and in the event of the occupier failing to comply with such requisition within two months from the date of the notice, sub-rule (I) shall cease to apply to such part of a factory, unless the Chief Inspector otherwise determines. [THE SCHEDULE
(1) Blast furnaces.
(2) Brick and tile works in which unglazed bricks or tiles are made.
Cement works.
Chemical works.
Copper mills.
Gas works.
Iron and steel mills.
Stone, slate and marble works.
The following parts of factories:
(a) Rooms used only for the storage of articles.
(b) Rooms in which the walk of ceilings consist of galvanized iron, glazed bricks. glass, slate, asbestos, bamboo thatch.
(c) Parts in which dense steam is continuously evolved in the process.
(d) Parts in which pitch, tar or like material is menu-factored or is used to a substantial extent, except in brush works. The parts of a glass factory known as the glass house. Rooms in which graphite is manufactured or is used to a substantial extent in any process.
(e) Parts in which coal, coke, oxide of iron, ochre, lime or stone is crushed or ground.
(f) Parts of walls, partitions, ceilings or tops of rooms which are at least 20 feet above the floor.
(g) Ceiling or tops of rooms in print works bleach works or dye works. with the exception of finishing rooms or warehouses.
(h) Inside walls of oil mills below a height of 5 feet from the ground floor level.
(i) Inside walls in tanneries below a height of 5 feet from the ground floor level where a wet process is carried on. Part B
(1) Coach and motor body work.
(2) Electric generating or transforming stations.
(3) Engineering works.
(4) Factories in which sugar is refined or manufactured.
(5) Foundries other than foundries in which brass casting is carried on.
(6) Gun factories.
(7) Shipbuilding works.
(8) Those parts of factories where unpainted or unvarnished wood is manufactured.]
16.Record of whitewashing, etc.
The record of dates on which whitewashing, colour-washing, varnishing, are carried out shall be entered in a register maintained in Form No. 7.
17.Disposal of trade wastes and effluents
In every factory, effective arrangements shall be made for the treatment of wastes and effluents due to the manufacturing processes carried on therein and the arrangements so made shall be in accordance with those approved by the relevant authorities of Tamil Nadu Pollution Control Board appointed under the Water (Prevention and Control of Pollution) Act, 1974 and the Air (Prevention and Control of Pollution) Act, 1981 and the authorities of Department of Environment.)
17A.Ventilation and temperature
1. Limits of temperature and air movement In any factory the maximum wet bulb temperature of air in a workroom at a height of 1.5 meters (5 feet) above the floor level shall not exceed 30 ° C (86F) and adequate air movement of at least 30 meters per minute (100 feet per minute) shall be provided; and in relation to dry bulb temperature the wet bulb temperature in the workroom at the said height shall not exceed that shown in the Schedule, or as regards a dry bulb reading intermediate between the two dry bulb readings that specified in relation to the higher of these two dry bulb readings. THE SCHEDULE Dry Bulb Temperatures Wet Bulb Temperature o o o o (C) (F) (C) (F) 30 (86) 29.0 (84.2) 31 (87.8) 28.9 (84.0) 32 (89.6) 28.8 (83.8) 33 (91.4) 28.7 (83.6) 34 (93.2) 28.6 (83.5) 35 (95) 28.5 (83.4) 36 (96.8) 28.4 (83.2) 37 (98.6) 28.3 (83.0) 38 (100.4) 28.2 (82.7) 39 (102.2) 28.1 (82.6) 40 (104) 28.0 (82.5) 41 (105.8) 27.9 (82.3) 42 (107.6) 27.8 (82.1) 43 (109.4) 27.7 (81.9) 44 (111.2) 27.6 (81.7) 45 (113) 27.5 (81.5) 46 (114.8) 27.4 (81.3) 47 (116.6) 27.3 (81.1)
Provided that if the temperature measured with a thermometer inserted in a hollow globe of 15 c.m. (6 inches) dia, coated mat black outside and kept in the environment for not less than 20 minutes exceeds the dry bulb temperature of air, the temperature so recorded by the globe thermometer shall be taken in place of the dry bulb temperature:
Provided further that when the reading of the wet bulb temperature outside in the shade exceeds 27 ° C (80.6 ° F) the value of the wet bulb temperature allowed in the Schedule for a given dry bulb temperature may be correspondingly exceeded to the same extent:
Provided also that this requirement shall not apply in respect of factories covered by section 15 and in respect of factories where the nature of work carried on involves production of excessively high temperatures referred to in clause (ii) of sub-section (I) to which workers are exposed for short periods of time not exceeding one hour followed by an interval of sufficient duration in thermal environments not exceeding those otherwise laid down in this rule:
Provided also that, the Chief Inspector having due regard to the health of the worker may in special and exceptional circum-stances, by an order in writing, exempt any factory or part of a factory from the foregoing requirement, in so far as restricting the thermal conditions within the limits laid down in the Schedule are concerned, to the extent that he may consider necessary, subject to such conditions as he may specify.
2. Provision of Thermometers
(1) If it appears to the Inspector that in any factory, the temperature of air in a workroom is sufficiently high and is likely to exceed the limits prescribed in rule (1) he may serve on the manager of the factory an order requiring him to provide sufficient number of whirling hygrometers or any other type of hygrometers and direct that the dry bulb and wet bulb readings in each such workroom shall be recorded at such positions as approved by the Inspector twice during each working shift by a person especially nominated for the purpose by the manager and approved by the Inspector.
(2) If the Inspector has reason to believe that a substantial amount of heat is added inside the environment of a workroom by radiation from walls, roof or other solid surroundings, he may serve on the manager of the factory an order requiring him to provide one or more globe thermometers referred to in the first proviso in rule (I) and further requiring him to place the globe thermometers at places specified by him and keen a record of the temperatures in a suitable register.
3. Ventilation
(1) In every factory the amount of ventilating openings in a workroom below the caves shall, except where mechanical means of ventilation as required by sub- rule (2) are provided, be of as aggregate area of not less than 15 per cent of the floor area and so located as to afford a continued supply of fresh air:
Provided that the Chief Inspector may relax the requirements regarding the amount of ventilating openings if he is satisfied that having regard to the location of the factory, orientation of the workroom, prevailing winds, roofs height and the nature of manufacturing process carried on, sufficient supply of fresh air into the workroom is afforded during most part of the working time:
Provided further that these requirements shall not apply in respect of workrooms of factories
(i) Covered by section 15; or
(ii) in which temperature and humidity are controlled by refrigeration.
(2) Where in any factory owing to special circumstances such a situation with respect to adjacent buildings and height of the building with respect to floor space, the requirements of ventilation openings under sub-rule (1) cannot be complied with or in the opinion of the Inspector the temperature of air in a workroom is sufficiently high and is likely to exceed the limits prescribed in sub-rule (I), he may serve on the manager of the factory an order requiring him to provide additional ventilation either by means of roof ventilators or by mechanical means.
(3) The amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the workroom and shall be distributed evenly throughout the workroom without dead air pockets or undue draughts caused by high inlet velocities.
(4) In regions where in summer (15th March-15th July) dry bulb temperatures of outside air in the shade during most part of the day exceed 35 ° C (95 ° F) and simultaneous wet bulb temperatures are 25 ° C (67 ° F) or below and in the opinion of the Inspector the manufacturing process carried on in the workroom of a factory permits thermal environments with relative humidity of 50 per cent or more, the Inspector may serve on the manager of the factory an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (desert coolers) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of central air washing plants.
18.When artificial humidification not allowed
There shall be no artificial humidification in any room of a cotton spinning or weaving factory
(a) By the use of steam during any period, when the dry bulb temperature of that room o o exceeds [85 F or 29.5 C]
(b) At any time when the wet bulb reading of the hygrometer in higher than that specified in the following schedule in relation to the dry bulb reading of the hygrometer at the time; or as regards a dry bulb reading intermediate between any two dry bulb reading indicated consecutively in the schedule, when the wet bulb reading is higher than that specified in relation to the higher of these two dry bulb readings: *[THE SCHEDULE Dry Bulb Temperatures Wet Bulb Temperature o o o o (F) (C) (F) (C) 60.0 15.5 58.0 14.5 61.0 16.0 59.0 15.0 62.0 16.5 60.0 15.5 63.0 17.0 61.0 16.0 64.0 18.0 62.0 16.5 65.0 18.5 63.0 17.0 66.0 19.0 64.0 18.0 67.0 19.5 65.0 18.5 68.0 20.0 66.0 19.0 69.0 20.5 67.0 19.5 70.0 21.0 68.0 20.0 71.0 21.5 69.0 20.5 72.0 22.0 70.0 21.0 73.0 23.0 71.0 21.5 74.0 23.5 72.0 22.0 75.0 24.0 73.0 23.0 76.0 24.5 74.0 23.5 77.0 25.0 75.0 24.0 78.0 25.5 76.0 24.5 79.0 26.0 77.0 25.0 80.0 26.5 78.0 25.5 81.0 27.0 79.0 26.0 82.0 28.0 80.0 26.5 83.0 28.5 80.5 27.0 84.0 29.0 81.0 27.5 85.0 29.5 82.0 28.0 86.0 30.0 82.5 28.0 87.0 30.5 83.0 28.5 88.0 31.0 83.5 28.5 89.0 31.5 84 29.0 90.0 32.0 84.5 29.0 91.0 33.0 85.0 29.5 92.0 33.5 85.5 30.0 93.0 34.0 86.0 30.0 94.0 34.5 86.0 30.0 95.0 35.0 87.0 60.5 96.0 35.5 87.5 31.0 97.0 36.0 88.0 31.0 98.0 37.0 88.5 31.5 99.0 37.5 89.0 32.0 100.0 38.0 89.5 32.0 101.0 38.5 90.0 32.5 102.0 39.0 90.0 32.5 103.0 39.5 90.5 32.5 104.0 40.0 90.5 32.5 105.0 40.5 91.0 33.0 106.0 41.0 91.0 33.0 107.0 41.5 91.0 33.0 108.0 42.0 91.5 33.0 109.0 43.0 92.0 33.5 110.0 43.5 92.0 33.5
Provided, however, that clause (b) shall not apply when the difference between the wet bulb temperature as indicated by the hygrometer in the department concerned and the o wet bulb temperature taken with a hygrometer outside in the shade is less than [35 F or 2 C];
Provided further that when the reading of the wet bulb temperature outside in the shade exceeds [80 F or 27 C], the value of the web bulb temperature allowed in the schedule for a given dry bulb temperature may be correspondingly exceeded to the same extent.
19.Provision of hygrometer
In all departments of cotton spinning and weaving mills wherein artificial humidification is adopted, hygrometers shall be provided and maintained in such positions as are approved by the Inspector. The number of hygrometers shall be regulated according to the following scale:
(a) Weaving Department: One hygrometer for departments with less than 500 looms, and one additional hygrometer for every 500 or part of 500 looms in excess of 500.
(b) Other Departments: One hygrometer for each room of less than 8,495 cubic meters capacity and one extra hygrometer for each 5,663.4 cubic meters or part thereof, in excess of this.
(c) One additional hygrometer shall be provided and maintained outside each cotton spinning and weaving factory wherein artificial humidification is adopted and in a position approved by the Inspector, for taking hygrometer shade readings.
20.Exemption from maintenance of hygrometers
When the Inspector is satisfied that the limits of humidity allowed by the schedule to rule 18 are never exceeded, he may, for any department other than the weaving department, grant exemption from the maintenance of the hygrometer. The Inspector shall record such exemption in writing.
21.Copy of schedule to rule 18 to be affixed near every hygrometer
A legible copy of the schedule to rule 18 shall be affixed near each hygrometer.
22.Temperature to be recorded at each hygrometer
At each hygrometer maintained in accordance with rule 19, correct wet and dry bulb temperatures shall be recorded thrice daily during each working day by competent persons nominated by the manager and approved by the Inspector. The temperature shall be taken between 7 a.m. and 9 a.m., between 11 a.m. and 2 p.m. (but not in the rest interval) and between4 p.m. and 5.30 p.m. In exceptional circumstances, such additional readings and between such hours, as the Inspector may specify, shall be taken. The temperatures shall be entered in a Humidity Register in the prescribed Form No. 6, maintained in the factory. At the end of each month, the pet sons who have taken the readings shall sign the register and certify the correctness of the entries. The register shall always be available fen inspection by the Inspector.
23.Specifications of hygrometer
Each hygrometer shall comprise two mercurial thermometers of wet bulb and dry bulb of similar construction, and equal in dimensions, scale and divisions of scale. They shall be mounted on a frame with a suitable reservoir containing water.
The wet bulb shall be closely covered with a single layer of muslin, kept by means of a wick attached to it and dropping into the water in the reservoir. The muslin covering and the wick shall be suitable for the purpose, clean and free from size or grease.
No part of the wet bulb shall be within 7.6 centimeters from the dry bulb or less than 2.5 centimeters from the surface of the water in the reservoir and the water reservoir shall be below it, or the side of it away from the dry bulb.
The bulb shall be spherical and of suitable dimensions and shall be freely exposed on all sides to the air of the room.
The bores of the stems shall be such that the position of the top of the mercury column shall be readily distinguishable at a distance of 61 centimeters.
Each thermometer shall be graduated so that accurate readings may be taken between [10 and 48.9 degrees].
Every degree from [10 degree up to 48.9 degrees] shall be clearly marked by horizontal lines on the stem each fifth and tenth degree shall be marked by longer marks than the intermediate degrees and the temperature marked opposite each tenth degree, [10, 15.6, 21.1, 26.7, 32.2,37.8, 43.3 and 48.9].
The markings as above shall be accurate, that is to say, at no temperature between [I0 and 48.9 degrees] shall the indicated readings be in error by more than two- tenths of a degree.
A distinctive number shall be indelibly marked upon the thermometer.
The accuracy of each thermometer shall be certified by the National Physical Laboratory, London, or some competent authority appointed by the Chief Inspector and such certificate shall be attached to the Humidity Register.
24.Thermometers to be maintained In efficient order
Each thermometer shall be maintained at all times during the period of employment in efficient working order so as to give accurate indications and in particular
(a) the wick and the muslin covering of the wet bulb shall be renewed once a week;
(b) the reservoir shall be filled with water which shall be completely renewed once a day. The Chief Inspector may direct the use of distilled water or pure rain water in any particular mill or mills in certain localities;
(c) no water shall be applied directly to the wick or covering during the period of employment.
25.An inaccurate thermometer not to be used without fresh certificate
If an Inspector gives notice in writing that a thermometer is not accurate, it shall not, after one month from the date of such notice, be deemed to be accurate unless until it has been re-examined at prescribed and a fresh certificate obtained which certificate shall be kept attached to the Humidity register.
26.Hygrometer not to be affixed to wall etc.. unless protected by wood
No hygrometer shall be affixed to a wall pillar, or other surface unless protected there from by wood or other non-conducting material at least 12.7 millimeters in thickness and distant at least 2.5 centimeters from the bulb of each thermometer.
No hygrometer shall be fixed at a height of more than 1.7 meters from the floor to the top of thermometer stem or in the direct draughts from a fan, window, or ventilating opening.
27.No reading to be taken within 15 minutes of renewal of water
No leading shall be taken for record on any hygrometer within 15 minutes of the renewal of water in the reservoir.
28.How to introduce steam for humidification
In any room in which steam pipe are used for the introduction of steam for the purpose of artificial humidification of the air, the following provisions shall apply
(a) The diameter of such pipe shill not exceed 5.1 centimeters and in the case of pipes are installed after 1st day of April, 1949, the diameter shall not exceed 2.5 centimeters.
(b) Such pipes shall be as short as is reasonably practicable.
(c) All hangers supporting such pipes shall be separated from the bare pipes by an efficient insulator not less than 12.7 millimeters in thickness.
(d) No unrecovered jet from such pipe shall project more than 11.5 centimeters beyond the outer surface of any cover.
(e) The steam pressure shall be as low as practicable and shall not exceed 31.8 kg. per square centimeter.
(f) The pipe employed for the introduction of steam into the air in a department shall be effectively covered with such non-conducting material, as may be approved by the Inspector in order to minimize the amount of heat radiated by them into the department.
29.Lighting Application and commencement
Subject as in these rules provided, rules 29 to 33 shall apply to factories in which persons are being regularly employed in a manufacturing process or processes for more than 48 hours a week, or in shifts, provided that nothing in these rules shall be deemed to require the provision of lighting of a specified standard in any building or structure so constructed that, in the opinion of the Chief Inspector, it would not be reasonably practicable to comply with such requirement.
Rules 29 to 33 shall come into force, in respect of any class or description of factories, on such dates as the State Government may, by notification in the Official Gazette, appoint in this behalf.
30.Lighting of interior parts
The general illumination over those interior parts of a factory where persons are regularly employed shall he not less than [65 lux] measured in the horizontal plane at a level of 91.4 centimeters above the floor:
Provided that in any such parts in which the mounting height of the light source for general illumination necessarily exceeds 7.6 meters measured from the floor or where the structure of the room or the position or construction of the fixed machinery or plant prevents the uniform attainment of this standard, the general illumination at the said level shall be not less than [22 lux] and where work is actually being done the illumination shall be not less than [65 lux).
The illumination over all other interior parts of the factory over which persons employed pass, shall, when and where a person is passing, be not less than [5.5 lux] at floor level.
The standard specified in this rule shall be without prejudice to the provision of any additional illumination required to render the lighting sufficient and suitable for the nature of the work.
31.Prevention of glare
Where any source of artificial light in the factor is less than 4.9 meters above floor level, no part of the light source or of the lighting fitting having a brightness greater than 15 candles per square centimeters shall be visible to persons whilst normally employed within 30.5 meters of the source except where the angle of elevation from the eye to the source or part of the fitting as the case may be exceeds 20
Any local light, that is to say. an artificial light designed to illuminate particularly the area or part of the area of work of a single operative or small group of operatives working near each other, shall be provided with a suitable shade of opaque material to prevent glare or with other effective means by which the tight source is completely screened from the eyes of every person employed at a normal working place, or shall be so placed that no such person is exposed to glare there from.
32.Power of Chief Inspector to exempt
Where the Chief Inspector is satisfied in respect of any particular factory or part thereof or in respect of any description of workroom or process that any requirement of rules 29 to 31 is inappropriate or is not reason-ably practicable, he may, by order in writing, exempt the factory or part thereof, or description of workroom or process from such requirement to such extent and subject to such conditions as he may specify.
33.Exemption from rule 30
Nothing in rule 30 shall apply to the parts of factories specified in Part I of the Schedule annexed hereto.
Nothing in sub-rule (1) of rule 30 shall apply to the factories or parts of factories respectively specified in Part II of the said Schedule.
34.Quantity of drinking water
The quantity of drinking water to be provided for the workers in every factory shall be at least 4.5 liters per day per worker and such drinking water shall be readily available at all times during working hours.
35.Source of supply
The water provided for drinking shall be supplied
(a) from a public water supply system, or
(b) from any other source approved in writing by the Health Officer.
36.Means of supply
If drinking water is not supplied directly from taps either connected with public water- supply system or any other water supply system of the factory approved by the Health Officer, it shall be kept in suitable vessels, receptacles or tanks fitted with taps, and having dust proof covers placed on raised stands or platforms in shade and having suitable arrangements of drainage to carry away spilt water. Such vessels or receptacles and tanks shall be kept clean and the water renewed at least once every day. All practicable measures shall be taken to ensure that the water is free from contamination.
37.Cleanliness of well or reservoir
Drinking water shall not be supplied from any open well or reservoir unless it is constructed, situated, protected and maintained as to be free from the possibility of pollution by chemical or bacterial and extraneous impurities.
Where drinking water is supplied from such well or reservoir the water in it shall be sterilized once a week or more frequently if the Inspector, by written order, so requires, and the date on which sterilizing is carried out shall be recorded:
Provided that this requirement shall not apply to any such well or reservoir if the water therein is filtered and treated to the satisfaction of the Health Officer before it is supplied for consumption.
38.Report from Health Officer
The Inspector may, by order in writing, direct the Manager to obtain, at such time or at such intervals as he may direct, a report from the Health Officer as to the fitness for human consumption of the water supplied to the workers, and in every ease to submit to the Inspector a copy of such report as soon as it is received from the Health Officer.
39.Cooling of water
In every factory wherein more than two hundred and fifty workers are ordinarily employed
(a) the drinking water supplied to the workers shall, during hot weather, be cooled by ice or other effective method:
Provided that, if ice is placed in the drinking water, the ice shall be clean and wholesome and shall be obtained only from a source approved in writing by the Health Officer;
(b) the cooled drinking water shall be supplied in every can-teen, lunch-room and rest- room and also at conveniently accessible points throughout the factory which fur the purpose of these rules shall be called "Water Centers";
(c) the water centers shall be sheltered from the weather and adequately drained;
(d) the number of water centers to be provided shall be one "centre" for every 150 persons employed at any one lime in the factory.
Provided that in the case of a factory where the number of persons employed exceeds 500, it shall be sufficient if there is one such "centre" as aforesaid for every 150 persons up to the first 500 and one for every 500 persons thereafter.; [Provided further that the distance between the places of work of any worker shall not be more than fifty meters from the nearest water centre or any distance as may be specified by the Inspector.]
(e) every water centre shall be maintained in a clean and orderly condition;
(f) every water centre shall be in charge of a suitable person who shall distribute the water. Such person shall be provided with clean clothes while on duty:
Provided that, the Chief Inspector may exempt any "water centre" from the requirements of this clause.
Clause (f) shall not apply to any factory in which suitable mechanically operated drinking water refrigerating units are installed to the satisfaction of the Chief Inspector.
40.Latrine Accommodation
Latrine accommodation shall be provided in every factory on the following scale:
(a) Where women are employed, there shall be at least one latrine seat for every 20 women;
(b) Where males are employed, there shall be at least one latrine scat for every 20 males:
Provided that, where the number of males employed exceeds 100, it shall be sufficient if there is one latrine scat for every 20 males up to the first 100, and one for every 50 thereafter.
In calculating the number of seats required under this rule, any odd number of workers less than 20 or 50, as the case may be, shall be reckoned as 20 or 50 and the maximum number of persons working in the factory at any time and not the total number of persons employed in the factory, shall be taken into account.
41.Latrines to conform to public health requirements
Latrines other than those connected with an efficient water-home sewage system, shall comply with the requirements of the Public Health authorities.
42.Privacy of latrines
Every latrine shall be under cover and every seat in the latrine shall be so partitioned off as to secure privacy and each partition shall have a proper door and fastenings.
43.Signboards to be displayed
Where workers of both sexes are employed there shall be displayed outside each latrine block a notice in the language understood by the majority of the workers "For Men only —
or "For Women only", as the case may be. The notice shall also bear the figure of "a man" or of "a woman", as the case may be.
44.Urinal accommodation
Urinal accommodation shall be provided for the use of workers and shall not be less than 61 centimeters in length for every 50 workers: provided that, where the number of workers employed exceeds 500, it shall be sufficient if there is one urinal for every 50 workers up to the first 50X) employed and one for every 100 thereafter. Where women are employed, separate urinal accommodation shall he provided for them on the same scale as mentioned above:
Provided further that the Chief Inspector of Factories may by order in writing exempt.
subject to such conditions as he may think fit to impose, small factories employing less than 20 'workers from the provision of separate urinal accommodation if he is satisfied that the latrine accommodation in such factories is sufficient and suitable.
In calculating the urinal accommodation required under sub-rule (1), any odd number of workers less than 50 or 100,as the case may be, shall be reckoned as 50 or 100, and the maximum number of persons working in the factory, at any time and not the total number of persons employed in the factory, shall be taken into account.
45.Urinals to conform to public health requirements
Urinals other than those connected with efficient water borne sewage system, and urinals in a factory wherein more than two hundred and fifty workers are ordinarily employed shall comply with the requirements of the Public Health authorities.
46.Certain latrines and urinals to be connected to sewage system
When any general system of underground sewerage with an assured water-supply for any particular locality is provided in a municipality all latrines and urinals other than septic tank latrines and any other type of latrines and urinals to be approved for this purpose by the Public Health authority, of a factory situated in such locality shall, if the factory is situated within 30.5 meters of an existing sewer, be connected with that sewage system.
47.Whitewashing and colourwashing of latrines and urinals
The walls, ceilings and partitions of every latrine and urinal shall be white-washed or colourwashed and the whitewashing or colourwashing shall be repeated at least once in every period of four months. The dates on which the whitewashing or colour washing is carried out shall be entered in the prescribed register (Form No. 7):
Provided that this rule shall not apply to latrines and urinals, the walls, ceiling, or partitions of which are laid in glazed tiles or otherwise finished to provide a smooth polished impervious surface and that they are washed with suitable detergents and disinfectants at least once in every period of four months.
48.Construction and maintenance of drains
All drains carrying waste or spoilage water shall be constructed in masonry or other impermeable materials and shall be regularly flushed and effluent disposed of by connecting such drains with a suitable drainage line:
Provided that, where there is no such drainage line, the effluent shall be deodorized and rendered innocuous and then disposed off in suitable manner to the satisfaction of the Health Officer.
49.Water taps in latrines
Where piped water-supply is available a sufficient number of water taps, conveniently access shall be provided in or near such latrine accommodation. Where there is no continuous supply of water, water cisterns with cans should be provided for washing purposes.
50.Number and location of spittoons
The number and location of the spittoons to be provided shall be to the satisfaction of the Inspector.
51.Type of spittoons
The spittoons shall be of either of the following types:
(a) A galvanized iron container with a conical funnel shaped cover. A layer of suitable disinfectant liquid shall always be maintained in the container, or
(b) a container filled with dry clean sand and covered with a layer of bleaching powder, or
(c) any other type approved by the Chief Inspector.
52.Cleaning of spittoons
The spittoons mentioned in clause (a) of rule 51 shall be emptied, cleaned and disinfected at least once every day and the spittoon mentioned in clause (b) of rule 51 shall be cleaned by scrapping out the top layer of sand as often as necessary or at least once every day.
52-A.Planting of trees
[The occupier of every factory employing one hundred or more workers shall plant and maintain trees within the premises of the factory. The number, type and layout of trees shall be approved by the District Agricultural Officer concerned:
Provided that if it is not possible to plant trees due to non-availability of space in any factory or class of factories, the District Agricultural Officer may recommend to the Government for grant of exemption to such factory or class of factories from the provisions of this rule.]